Thiết bị chuyển mạch cisco Nexus N3K-C3048TP-1GE

Thiết bị chuyển mạch cisco Nexus N3K-C3048TP-1GE

Nexus 3048TP-1GE 1RU 48 x 10/100/1000 and 4 x 10GE ports

  • Ports: 48 x 10/100/1000 + 4 x 10 Gigabit SFP+

 

  • Mô tả

Mô tả

 

Specification (N3K-C3048TP-1GE)

N3K-C3048TP-1GE Specification

Physical· 1RU fixed form-factor switch

· 48 10/100/1000-Mbps RJ-45 ports

· 4 1/10 Gbps SFP+ uplink ports

· 2 redundant power supplies

· 1 fan tray with redundant fans

· 1 I/O module with management, console, and USB flash memory ports

Performance· 176-Gbps switching capacity

· Forwarding rate of 132 mpps

· Line-rate traffic throughput (both Layer 2 and 3) on all ports

· Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames)

Hardware tables and scalability

MAC addresses128,000
Number of VLANS4096
Spanning-tree instances· RSTP: 512

· MSTP: 64

ACL entries2000 ingress

1000 egress

Routing table16,000 prefixes and 16,000 host entries

8000 multicast routes

Number of EtherChannels52 (with vPC)
Number of ports per EtherChannel16
Buffers9 MB shared
Boot flash memory2 GB

Power

Number of power supplies2 (redundant)
Typical operating power120 watts (W) (48p of 1G and 4p of 10G/SR at 100% load, with 2 power supply units [PSUs])
Maximum power124W
AC PSUs

Input voltage

Frequency

Efficiency

 100 to 240 VAC

50 to 60 Hz

89 to 91% at 220V

DC PSUs

Input voltage

Maximum current

Efficiency

 -40 to -72 VDC

33A

85 to 88%

Typical heat dissipation409 BTU/hr (48p of 1G and 4p of 10G/SR at 100% load, with 2 PSUs)
Maximum heat dissipation423 BTU/hr
CoolingForward and reversed airflow schemes

Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)

Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)

Single fan tray with redundant fans

Hot swappable (must swap within 1 minute)

Sound

Measured sound power (maximum)

Fan speed: 40% duty cycle

Fan speed: 60% duty cycle

Fan speed: 100% duty cycle

63.9 dBA

64.7 dBA

66.4 dBA

Environment

Dimensions (height x width x depth)1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm)
Weight20.5 lb (9.3 kg)
Operating temperature32 to 104°F (0 to 40°C)
Storage temperature-40 to 158°F (-40 to 70°C)
Operating relative humidity10 to 85% noncondensing

Up to 5 days at maximum (85%) humidity

Recommend ASHRAE data center environment

Storage relative humidity5 to 95% noncondensing
Altitude0 to 10,000 ft (0 to 3000m)